Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Details for DDEntity "36865 - Range DDI 2"

36865 - Range DDI 2 Request changes
DefinitionThe minimum droplet size the system can produce. Defined as:
0 = Unknown,
1 = Extremely Fine - XF,
2 = Very Fine - VF,
3 = Fine - F,
4 = Medium - M,
5 = Coarse - C,
6 = Very Coarse - VC,
7 = Extremely Coarse - XC,
8 = Ultra Coarse - UC,
9-254 = Reserved,
255 = No Droplet Size Available.
CommentDroplet sizes are currently defined in ISO 25358 and are broken into 8 classification categories and also assigned a corresponding colour code as follows:
Extremely Fine = Purple,
Very Fine = Red,
Fine = Orange,
Medium = Yellow,
Coarse = Green,
Very Coarse = Blue,
Extremely Coarse = White,
Ultra Coarse = Black
Typically used by Device Class(es) 4 - Planters /Seeders
5 - Fertilizer
6 - Sprayers
10 - Irrigation
17 - Sensor System
Unit Symboln.a. - not applicable
Bit Resolution1
SAE SPN
CANBus Range0 to 255
Display Range0 to 255
Submit Date2021-03-08
Submit CompanyTeeJet Technologies
Revision Number1
Current StatusPublished
Status Date2021-05-12
Status Comments
2021-05-12: Published

Back