Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF0Minimum Control Function(Byte 1) 0000 0000No optionsDetails →
CFF0Minimum Control Function(Byte 1) 0000 0001Type I ECU – Internal weak termination Details →
CFF0Minimum Control Function(Byte 1) 0000 0010Type II ECU – Internal end-point terminationDetails →
CFF0Minimum Control Function(Byte 1) 0000 0100Support of Heartbeat producerDetails →
CFF0Minimum Control Function(Byte 1) 0000 1000Support of Heartbeat consumerDetails →
CFF0Minimum Control Function(Byte 1) bits 5 to 8Reserved for ISO assignmentDetails →
CFF1Universal Terminal (UT) Server(Byte 1) 0000 0000No optionsDetails →
CFF1Universal Terminal (UT) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF2Universal Terminal (UT) Client(Byte 1) 0000 0000No optionsDetails →
CFF2Universal Terminal (UT) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF3Aux-O inputs(Byte 1) 0000 0000No optionsDetails →
CFF3Aux-O inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF3Aux-O inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF3Aux-O inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF3Aux-O inputs(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF4Aux-O functions(Byte 1) 0000 0000No optionsDetails →
CFF4Aux-O functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF4Aux-O functions(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF5Aux-N inputs(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF5Aux-N inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF5Aux-N inputs(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF5Aux-N inputs(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF5Aux-N inputs(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF5Aux-N inputs(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF5Aux-N inputs(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF5Aux-N inputs(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF5Aux-N inputs(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF5Aux-N inputs(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF5Aux-N inputs(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF6Aux-N functions(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF6Aux-N functions(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF6Aux-N functions(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF6Aux-N functions(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF6Aux-N functions(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF6Aux-N functions(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF6Aux-N functions(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF6Aux-N functions(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF6Aux-N functions(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) 0000 0000No optionsDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) 0000 0000No optionsDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 1) 0 to 255Number of control channelsDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0001Polygon-based prescription maps are supportedDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) bits 2 to 8Reserved for ISO assignmentDetails →
CFF10Task Controller Geo (TC-GEO) Client(Byte 1) 0 to 255Number of control channelsDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 1) 1 to 255Number of supported boomsDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 1) 1 to 255Number of supported boomsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0100Lighting option (L)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 1000Navigation option (N)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0001 0000Front hitch option (F)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0010 0000Guidance option (G)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0100Class required lighting (L)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 1000Navigation option (N)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0001 0000Front hitch option (F)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0010 0000Guidance option (G)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0001Aux valve 1 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0010Aux valve 1 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0100Aux valve 2 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 1000Aux valve 2 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0001 0000Aux valve 3 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0010 0000Aux valve 3 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0100 0000Aux valve 4 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 1000 0000Aux valve 4 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0001Aux valve 5 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0010Aux valve 5 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0100Aux valve 6 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 1000Aux valve 6 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0001 0000Aux valve 7 state is supportedDetails →