Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 101-200 of 435 results.
| CFF / ECFF | Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|---|
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0001 0000 | Aux valve 31 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0001 0000 | Aux valve 31 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 1000 0000 | Aux valve 32 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 1000 0000 | Aux valve 32 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0100 0000 | Aux valve 32 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0100 0000 | Aux valve 32 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 1) 1000 0000 | Aux valve 4 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 1) 1000 0000 | Aux valve 4 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 1) 0100 0000 | Aux valve 4 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 1) 0100 0000 | Aux valve 4 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0010 | Aux valve 5 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0010 | Aux valve 5 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0001 | Aux valve 5 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0001 | Aux valve 5 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 1000 | Aux valve 6 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 1000 | Aux valve 6 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0100 | Aux valve 6 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0100 | Aux valve 6 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0001 0000 | Aux valve 7 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0001 0000 | Aux valve 7 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0100 0000 | Aux valve 8 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0100 0000 | Aux valve 8 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0001 | Aux valve 9 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0001 | Aux valve 9 state is supported | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 2 - 00001100 | Aux Valve N (N = 1 to 32) aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N config, bits 4 to 1 | Aux Valve N (N = 1 to 32) config (0x0 optional, 0x1 required) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 1 - 00110000 | Aux Valve N (N = 1 to 32) flow support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 1 - 00110000 | Aux Valve N (N = 1 to 32) flow support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 1 - 11000000 | Aux Valve N (N = 1 to 32) state support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 1 - 11000000 | Aux Valve N (N = 1 to 32) state support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 2 - 11000000 | Aux Valve N (N = 1 to 32) upper limit handling support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 2 - 00001100 | Aux Valve N (N = 1 to 32) valve function aggressiveness support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 2 - 11000000 | Aux Valve N (N = 1 to 32) valve upper limit handling support indication | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0001 | Class 1, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0001 | Class 1, no options | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0010 | Class 2, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0010 | Class 2, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0100 | Class required lighting (L) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4616 External Guidance - FacOptByte 1 - 11000000 | Curvature support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance - FacOptByte 1 - 11000000 | Curvature support indication | Details → |
| CFF | 24 | Datalogger (LOG) Server | (Byte 1) 0000 0001 | Data logger (LOG) service type supports FMIS interface | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4616 External Guidance - FacOptByte 2 - 00001100 | External Guidance aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance - FacOptByte 2 - 00001100 | External Guidance aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance config, bits 4 to 1 | External Guidance config (0x0 optional, 0x1 required) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4616 External Guidance - FacOptByte 2 - 11000000 | External Guidance upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance - FacOptByte 2 - 11000000 | External Guidance upper limit handling support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 2 - 11000000 | Forward direction, speed set by TIM server support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 2 - 11000000 | Forward direction, speed set by TIM server support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4216 Front Hitch - FacOptByte 2 - 00001100 | Front Hitch aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 2 - 00001100 | Front Hitch aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch config, bits 4 to 1 | Front Hitch config (0x0 optional, 0x1 required) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4216 Front Hitch - FacOptByte 1 - 11000000 | Front Hitch motion (raise/lower/float/stop) support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 1 - 11000000 | Front Hitch motion (raise/lower/float/stop) support indication | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0001 | Front hitch motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0001 | Front hitch motion is supported | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0001 0000 | Front hitch option (F) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0001 0000 | Front hitch option (F) | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0010 | Front hitch position is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0010 | Front hitch position is supported | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4216 Front Hitch - FacOptByte 1 - 00110000 | Front Hitch position support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 1 - 00110000 | Front Hitch position support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4216 Front Hitch - FacOptByte 2 - 11000000 | Front Hitch upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 2 - 11000000 | Front Hitch upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO config, bits 4 to 1 | Front PTO config (0x0 optional, 0x1 required) | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0001 | Front PTO disengagement is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0001 | Front PTO disengagement is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0010 | Front PTO engagement CCW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0010 | Front PTO engagement CCW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0100 | Front PTO engagement CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0100 | Front PTO engagement CW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 1000 | Front PTO speed CCW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 1000 | Front PTO speed CCW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0001 0000 | Front PTO speed CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0001 0000 | Front PTO speed CW is supported | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4716 Front top linkage - FacOptByte 2 - 00001100 | Front Top linkage aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 2 - 00001100 | Front Top linkage aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage config, bits 4 to 1 | Front Top Linkage config (0x0 optional, 0x1 required) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4716 Front top linkage - FacOptByte 1 - 11000000 | Front Top linkage motion (extend/retract/float/stop) support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 1 - 11000000 | Front Top linkage motion (extend/retract/float/stop) support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4716 Front top linkage - FacOptByte 1 - 00110000 | Front Top linkage position support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 1 - 00110000 | Front Top linkage position support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4716 Front top linkage - FacOptByte 2 - 11000000 | Front Top linkage upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 2 - 11000000 | Front Top linkage upper limit handling support indication | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0001 | Guidance curvature is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0001 | Guidance curvature is supported | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0010 0000 | Guidance option (G) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0010 0000 | Guidance option (G) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0100 | Lighting option (L) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 1000 | Navigation option (N) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 1000 | Navigation option (N) | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 1 | Universal Terminal (UT) Server | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 2 | Universal Terminal (UT) Client | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0000 | No options | Details → |