| SPN | 2845 |
| SP Name | NAME of Working Set Member |
| SP Description | This parameter is a NAME with the format specified in ISO 117835 that identifies a member of a working set. This NAME is the same at that which was used by the member when it claimed its associated source address. |
| Sp Notes | Not set |
| Has Attachment | no |
| SP Historical Remarks | - |
| SP Historical Attachment | no |
| From 2015/2019 | 2015 |
| SP Length | 64 bits |
| Scaling | 1 count/bit |
| Offset | 0 |
| Data Range | 0 to 18446744073709551615 |
| Operational Range | Not set |
| Units | bit |
| Slot Identifier | 159 |
| Slot Name | SAEnm01 |
| SP Type | Measured |
| SP Reference | Not set |
| Scale Factor (value only) | 1 |
| Offset (value only) | 0 |
| Range maximum (value only) | 18446744073709551615 |
| Length minimum (value only) | 64 |
| Length maximum (value only) | 64 |
| SP Document | ISO 11783-7 |
| PG Created or Modified Date | 2000-08-10 |
| PG SP Mapping Created/Mod. Date | Not set |
Linked PGNs
Displaying 1-2 of 2 results.
| PGN | PG Label | |
| 64974 | Working Set Member Message (Obsolete - See PGN 65088) |  |
| 65036 | Working Set Member |  |