Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!
SPN1996
SP NameAuxiliary valve number 08 retract port measured flow
SP DescriptionMeasured flow through the retract port of auxiliary valve number 08 of a tractor, expressed as a percentage of full flow.

Zero percent indicates no flow, 100 % indicates maximum flow, −100 % indicates maximum flow returning to the tractor through this port.
Sp NotesNot set
Has Attachmentno
SP Historical Remarks-
SP Historical Attachmentno
From 2015/20192015
SP Length8 bits
Scaling1 %/bit
Offset-125
Data Range-125 to 125 %
Operational RangeNot set
Units%
Slot Identifier45
Slot NameSAEpc05
SP TypeMeasured
SP ReferenceNot set
Scale Factor (value only)1
Offset (value only)-125
Range maximum (value only)125
Length minimum (value only)8
Length maximum (value only)8
SP DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked PGNs

Displaying 1-1 of 1 result.
PGNPG Label 
65064Auxiliary valve 8 measured flowView