PGN65070
PG LabelAuxiliary valve 14 measured flow
PG AcronymAV14MF
PG NotesMessage that provides the measurement of auxiliary valve number 14 .
Pgn Notes-
EDP0
DP0
PF254
PS46
MultipacketNo
Transmission Rate100 ms
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit7.1
PG DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-6 of 6 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
2323Auxiliary valve number 14 extend port measured flow18 bits1 %/bit-125View
2324Auxiliary valve number 14 retract port measured flow28 bits1 %/bit-125View
2328Auxiliary valve number 14 extend port pressure3-416 bits5 kPa/bit0View
2329Auxiliary valve number 14 retract port pressure 5-616 bits5 kPa/bit0View
2330Auxiliary valve number 14 return port pressure78 bits16 kPa/bit0View
5188Auxiliary valve number 14 measured flow limit status8.63 bits8 states/3 bit0View