Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!
PGN65085
PG LabelAuxiliary valve 13 command
PG AcronymAV13C
PG NotesMessage that provides control of the flow through the auxiliary valve number 13.
Pgn Notes-
EDP0
DP0
PF254
PS61
MultipacketNo
Transmission Rate100 ms when active
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit3.1
PG DocumentISO 11783-7
PG Created or Modified Date2000-08-10
PG SP Mapping Created/Mod. Date2000-08-10

Linked SPNs

Displaying 1-5 of 5 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
2319Auxiliary valve number 13 port flow — Command18 bits0.4 %/bit0View
7885Auxiliary valve number 13 Resolution mode — Command2.12 bits4 states/2 bit0View
2320Auxiliary valve number 13 state — Command3.14 bits16 states/4 bit0View
2321Auxiliary valve number 13 fail safe mode — Command3.72 bits4 states/2 bit0View
7869Auxiliary valve number 13 port flow — Extended Resolution Command4-516 bits0.0015625 %/bit0View