Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!
PGN65092
PG LabelSecondary or Front Power Take off Output Shaft
PG AcronymFPTO
PG NotesMessage that provides the measurement of the current secondary or front power take-off (PTO) output shaft parameters.
Pgn Notes-
EDP0
DP0
PF254
PS68
MultipacketNo
Transmission Rate100 ms when engaged, otherwise on request
PG Data Length8
Default Priority3
PG ReferenceNot set
Sp Start Bit6.2
PG DocumentISO 11783-7
PG Created or Modified DateNot set
PG SP Mapping Created/Mod. DateNot set

Linked SPNs

Displaying 1-10 of 10 results.
SPNSP NameSP Position In PGSP LengthScalingOffset 
1882Front PTO output shaft speed1-216 bits0.125 1/min/bit0View
1884Front PTO Output Shaft Speed Set Point3-416 bits0.125 1/min/bit0View
5152Front PTO engagement request status5.12 bits4 states/2 bit0View
1891Front Power Take Off Economy Mode5.32 bits4 states/2 bit0View
1889Front Power Take Off Mode5.52 bits4 states/2 bit0View
1888Front Power Take Off Engagement5.72 bits4 states/2 bit0View
5155Front PTO shaft speed limit status 6.23 bits8 states/3 bit0View
5154Front PTO Economy mode request status6.52 bits4 states/2 bit0View
5153Front PTO mode request status 6.72 bits4 states/2 bit0View
5817Front PTO exit/reason code7.16 bits64 states/6 bit0View