| PGN | 65093 | 
|---|---|
| PG Label | Primary or Rear Hitch Status | 
| PG Acronym | RHS | 
| PG Notes | Message that provides the measurement of the current rear-hitch parameters. | 
| Pgn Notes | - | 
| EDP | 0 | 
| DP | 0 | 
| PF | 254 | 
| PS | 69 | 
| Multipacket | No | 
| Transmission Rate | 100 ms | 
| PG Data Length | 8 | 
| Default Priority | 3 | 
| PG Reference | Not set | 
| Sp Start Bit | 2.4 | 
| PG Document | ISO 11783-7 | 
| PG Created or Modified Date | Not set | 
| PG SP Mapping Created/Mod. Date | Not set | 
Linked SPNs
Displaying 1-6 of 6 results.
| SPN | SP Name | SP Position In PG | SP Length | Scaling | Offset | |
|---|---|---|---|---|---|---|
| 1873 | Rear Hitch Position | 1 | 8 bits | 0.4 %/bit | 0 |  | 
| 5151 | Rear Hitch Position Limit status | 2.4 | 3 bits | 8 states/3 bit | 0 |  | 
| 1877 | Rear Hitch In-work Indication | 2.7 | 2 bits | 4 states/2 bit | 0 |  | 
| 1881 | Rear Nominal Lower Link Force | 3 | 8 bits | 0.8 %/bit | -100 |  | 
| 1879 | Rear Draft | 4-5 | 16 bits | 10 N/bit | -320000 |  | 
| 5819 | Rear hitch exit/reason code | 6.1 | 6 bits | 64 states/6 bit | 0 |  |