| SPN | 8674 |
| SP Name | Auxiliary Valve 10 Flow |
| SP Description | This parameter is used to report the flow rate of auxiliary valve number 10 |
| Sp Notes | Not set |
| Has Attachment | no |
| SP Historical Remarks | - |
| SP Historical Attachment | no |
| From 2015/2019 | Not set |
| SP Length | 16 bits |
| Scaling | 0.004 % flow/bit |
| Offset | -128.512 |
| Data Range | -128.512 to 128.508 % |
| Operational Range | -128.512 to 128.508 % |
| Units | % |
| Slot Identifier | 497 |
| Slot Name | SAEpc28 |
| SP Type | Measured |
| SP Reference | Not set |
| Scale Factor (value only) | 0.004 |
| Offset (value only) | -128.512 |
| Range maximum (value only) | 128.508 |
| Length minimum (value only) | 16 |
| Length maximum (value only) | 16 |
| SP Document | ISO 11783-1 |
| PG Created or Modified Date | 2016-11-17 |
| PG SP Mapping Created/Mod. Date | 2017-02-21 |
Linked PGNs
Displaying 1-2 of 2 results.
| PGN | PG Label | |
| 8960 | Tractor Implement Management (TIM) Server to TIM Client |  |
| 15360 | Tractor Implement Management (TIM) Server to TIM Client - Control Status |  |
327763