CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF6Aux-N functions(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentDetails →
CFF25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) bits 2 to 8Reserved for ISO assignmentDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 9) bits 7 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) bits 6 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) bits 6 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) bits 3 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) bits 3 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 1000 0000Reserved for ISO assignmentDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 2 - 11000000Rear Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 2 - 11000000Rear Top linkage upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 1 - 00110000Rear Top linkage position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 1 - 00110000Rear Top linkage position support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 1 - 11000000Rear Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 1 - 11000000Rear Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage config, bits 4 to 1Rear Top Linkage config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 2 - 00001100Rear Top linkage aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 2 - 00001100Rear Top linkage aggressiveness support indicationDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0001 0000Rear PTO speed CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0001 0000Rear PTO speed CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 1000Rear PTO speed CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 1000Rear PTO speed CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0100Rear PTO engagement CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0100Rear PTO engagement CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0010Rear PTO engagement CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0010Rear PTO engagement CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0001Rear PTO disengagement is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0001Rear PTO disengagement is supportedDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO config, bits 4 to 1Rear PTO config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 2 - 11000000Rear Hitch upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4316 Rear Hitch - FacOptByte 2 - 11000000Rear Hitch upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 1 - 00110000Rear Hitch position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4316 Rear Hitch - FacOptByte 1 - 00110000Rear Hitch position support indicationDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) 0000 0010Rear hitch position is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0010Rear hitch position is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) 0000 0001Rear hitch motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0001Rear hitch motion is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 1 - 11000000Rear Hitch motion (raise/lower/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4316 Rear Hitch - FacOptByte 1 - 11000000Rear Hitch motion (raise/lower/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4316 Rear Hitch config, bits 4 to 1Rear Hitch config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 2 - 00001100Rear Hitch aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4316 Rear Hitch - FacOptByte 2 - 00001100Rear Hitch aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 3 - 11000000PTO upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 3 - 11000000PTO upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 3 - 11000000PTO upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 3 - 11000000PTO upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 00000011PTO speed counter-clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 00000011PTO speed counter-clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 1 - 00000011PTO speed counter-clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 1 - 00000011PTO speed counter-clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 2 - 11000000PTO speed clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 2 - 11000000PTO speed clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 2 - 11000000PTO speed clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 2 - 11000000PTO speed clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 3 - 00001100PTO function aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 3 - 00001100PTO function aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 3 - 00001100PTO function aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 3 - 00001100PTO function aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 00110000PTO engagement counter-clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 00110000PTO engagement counter-clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 1 - 00110000PTO engagement counter-clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 1 - 00110000PTO engagement counter-clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 00001100PTO engagement clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 00001100PTO engagement clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 1 - 00001100PTO engagement clockwise support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 1 - 00001100PTO engagement clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 11000000PTO disengagement support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 11000000PTO disengagement support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO - FacOptByte 1 - 11000000PTO disengagement support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4116 Rear PTO - FacOptByte 1 - 11000000PTO disengagement support indicationDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0001Polygon-based prescription maps are supportedDetails →
ECFF15Tractor Implement Management (TIM) Server(Byte 2) Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240)Details →
ECFF16Tractor Implement Management (TIM) Client(Byte 2) Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240)Details →
CFF11Task Controller Section Control (TC-SC) Server(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 1) 1 to 255Number of supported boomsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 1) 1 to 255Number of supported boomsDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 1) 0 to 255Number of control channelsDetails →
CFF10Task Controller Geo (TC-GEO) Client(Byte 1) 0 to 255Number of control channelsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0000No options for this option byte supportedDetails →
CFF5Aux-N inputs(Byte 1) 0000 0000No options for this option byte supportedDetails →