Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
ECFF15Tractor Implement Management (TIM) Server(Byte 1) Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFFDetails →
ECFF16Tractor Implement Management (TIM) Client(Byte 1) Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFFDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 00110000Vehicle Speed while driving in reverse direction support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 1 - 00110000Vehicle Speed while driving in reverse direction support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 11000000Vehicle Speed while driving in forward direction support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 1 - 11000000Vehicle Speed while driving in forward direction support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 3 - 11000000Vehicle speed upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 3 - 11000000Vehicle speed upper limit handling support indicationDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 1000Vehicle Speed stop motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 1000Vehicle Speed stop motion is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0100Vehicle Speed start motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0100Vehicle Speed start motion is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed config, bits 4 to 1Vehicle Speed config (0x0 optional, 0x1 required)Details →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0100 0000Vehicle Speed change direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0100 0000Vehicle Speed change direction is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 3 - 00001100Vehicle speed aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 3 - 00001100Vehicle speed aggressiveness support indicationDetails →
CFF0Minimum Control Function(Byte 1) 0000 0010Type II ECU – Internal end-point terminationDetails →
CFF0Minimum Control Function(Byte 1) 0000 0001Type I ECU – Internal weak termination Details →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlDetails →
ECFF16Tractor Implement Management (TIM) Client(Byte 3 +) - TIM Option Byte Structure Definition TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b, bits 4 to 1) TIM function ID config 0x0 - Optional 0x1 - Required 0x2 to 0xF - Reserved - (Byte c) Number of Facility Option Bytes (FacOptByte) to follow - (Byte d +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve #Count 1 to 32 (how many valves used by TIM client) 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1)Details →
ECFF15Tractor Implement Management (TIM) Server(Byte 3 +) - TIM Option Byte Structure DefinitionTIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b) Number of Facility Option Bytes (FacOptByte) to follow - (Byte c +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve 1 to 32 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF5Aux-N inputs(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF5Aux-N inputs(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF6Aux-N functions(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF5Aux-N inputs(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF6Aux-N functions(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF5Aux-N inputs(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF6Aux-N functions(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF5Aux-N inputs(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF6Aux-N functions(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF3Aux-O inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF5Aux-N inputs(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF6Aux-N functions(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF5Aux-N inputs(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF6Aux-N functions(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF5Aux-N inputs(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF6Aux-N functions(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF5Aux-N inputs(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF3Aux-O inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF3Aux-O inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationDetails →
CFF0Minimum Control Function(Byte 1) 0000 0100Support of Heartbeat producerDetails →
CFF0Minimum Control Function(Byte 1) 0000 1000Support of Heartbeat consumerDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 00000011Stop vehicle motion support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 1 - 00000011Stop vehicle motion support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 00001100Start vehicle motion support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 1 - 00001100Start vehicle motion support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 2 - 00110000Reverse direction, speed set by TIM server support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 2 - 00110000Reverse direction, speed set by TIM server support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) bits 2 to 8Reserved for ISO assignmentDetails →
CFF0Minimum Control Function(Byte 1) bits 5 to 8Reserved for ISO assignmentDetails →
CFF1Universal Terminal (UT) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF2Universal Terminal (UT) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 9) bits 7 to 8Reserved for ISO assignmentDetails →
CFF3Aux-O inputs(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) bits 6 to 8Reserved for ISO assignmentDetails →
CFF4Aux-O functions(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) bits 6 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 12) bits 3 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) bits 3 to 8Reserved for ISO assignmentDetails →
CFF5Aux-N inputs(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 1000 0000Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 15) bits 2 to 8Reserved for ISO assignmentDetails →
CFF17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →