Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 1-100 of 435 results.
| CFF / ECFF | Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|---|
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 1) | Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFF | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 1) | Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFF | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 1 - 00110000 | Vehicle Speed while driving in reverse direction support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 00110000 | Vehicle Speed while driving in reverse direction support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 1 - 11000000 | Vehicle Speed while driving in forward direction support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 11000000 | Vehicle Speed while driving in forward direction support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 3 - 11000000 | Vehicle speed upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 3 - 11000000 | Vehicle speed upper limit handling support indication | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed config, bits 4 to 1 | Vehicle Speed config (0x0 optional, 0x1 required) | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 3 - 00001100 | Vehicle speed aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 3 - 00001100 | Vehicle speed aggressiveness support indication | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0010 | Type II ECU – Internal end-point termination | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0001 | Type I ECU – Internal weak termination | Details → |
| CFF | 28 | Task Controller Tramline (TRACK) Client | (Byte 1) 0000 0001 | Tramline rythm transition | Details → |
| CFF | 28 | Task Controller Tramline (TRACK) Client | (Byte 1) 0000 0100 | Tramline control | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3 +) - TIM Option Byte Structure Definition | TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b, bits 4 to 1) TIM function ID config 0x0 - Optional 0x1 - Required 0x2 to 0xF - Reserved - (Byte c) Number of Facility Option Bytes (FacOptByte) to follow - (Byte d +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve #Count 1 to 32 (how many valves used by TIM client) 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3 +) - TIM Option Byte Structure Definition | TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b) Number of Facility Option Bytes (FacOptByte) to follow - (Byte c +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve 1 to 32 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0000 | TECU not meeting complete class 1 requirements | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0000 | TECU not meeting complete class 1 requirements | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 1000 0000 | Supports type 7 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 1000 0000 | Supports type 7 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0100 0000 | Supports type 6 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0100 0000 | Supports type 6 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0010 0000 | Supports type 5 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0010 0000 | Supports type 5 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0001 0000 | Supports type 4 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0001 0000 | Supports type 4 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 1000 | Supports type 3 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 1000 | Supports type 3 function | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 26 | ISOBUS System Information (INFO) Server | (Byte 1) 0000 0001 | Support of onboard visualization | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0100 | Support of Heartbeat producer | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 1000 | Support of Heartbeat consumer | Details → |
| CFF | 26 | ISOBUS System Information (INFO) Server | (Byte 1) 0000 0010 | Support of diagnostic data export | Details → |
| CFF | 26 | ISOBUS System Information (INFO) Server | (Byte 1) 0000 0100 | Support of CAN trace possibility | Details → |
| CFF | 28 | Task Controller Tramline (TRACK) Client | (Byte 1) 0000 0010 | Storage of implement track parameters | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 1 - 00000011 | Stop vehicle motion support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 00000011 | Stop vehicle motion support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 1 - 00001100 | Start vehicle motion support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 00001100 | Start vehicle motion support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4416 Vehicle Speed - FacOptByte 2 - 00110000 | Reverse direction, speed set by TIM server support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 2 - 00110000 | Reverse direction, speed set by TIM server support indication | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) bits 5 to 8 | Reserved for ISO assignment | Details → |
| CFF | 1 | Universal Terminal (UT) Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 2 | Universal Terminal (UT) Client | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 9) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) bits 4 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) bits 4 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) bit 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 1000 0000 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 17 | File Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 18 | File Server Client | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 19 | Sequence Controller (SQC) Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 20 | Sequence Controller (SQC) Client | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 21 | ISOBUS Shortcut Button (ISB) Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |