Displaying 101-200 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentDetails →
CFF3Aux-O inputs(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF4Aux-O functions(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF0Minimum Control Function(Byte 1) bits 5 to 8Reserved for ISO assignmentDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0001Front PTO disengagement is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0001Front PTO disengagement is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0010Front PTO engagement CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0010Front PTO engagement CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0100Front PTO engagement CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0100Front PTO engagement CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 1000Front PTO speed CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 1000Front PTO speed CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0001 0000Front PTO speed CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0001 0000Front PTO speed CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) bits 6 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) bits 6 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0001Rear PTO disengagement is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0001Rear PTO disengagement is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0010Rear PTO engagement CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0010Rear PTO engagement CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 0100Rear PTO engagement CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0100Rear PTO engagement CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0000 1000Rear PTO speed CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 1000Rear PTO speed CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) 0001 0000Rear PTO speed CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0001 0000Rear PTO speed CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 11) bits 6 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) bits 6 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 12) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 12) 0000 0001Front hitch motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0001Front hitch motion is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 12) 0000 0010Front hitch position is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0010Front hitch position is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 12) bits 3 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) bits 3 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) 0000 0001Rear hitch motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0001Rear hitch motion is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) 0000 0010Rear hitch position is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0010Rear hitch position is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) bits 3 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) bits 3 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0100Vehicle Speed start motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0100Vehicle Speed start motion is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 1000Vehicle Speed stop motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 1000Vehicle Speed stop motion is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0100 0000Vehicle Speed change direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0100 0000Vehicle Speed change direction is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 1000 0000Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 1000 0000Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 15) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) 0000 0001Guidance curvature is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 15) 0000 0001Guidance curvature is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) bits 2 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 15) bits 2 to 8Reserved for ISO assignmentDetails →
ECFF15Tractor Implement Management (TIM) Server(Byte 2) Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240)Details →
ECFF16Tractor Implement Management (TIM) Client(Byte 2) Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240)Details →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF5Aux-N inputs(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0001Aux valve 5 state is supportedDetails →
CFF5Aux-N inputs(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0001Polygon-based prescription maps are supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0001Aux valve 5 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0010Aux valve 5 flow is supportedDetails →
CFF5Aux-N inputs(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0010Aux valve 5 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0100Aux valve 6 state is supportedDetails →
CFF5Aux-N inputs(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0100Aux valve 6 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 1000Aux valve 6 flow is supportedDetails →