CFF / ECFFFunction NoMeaningValueMeaning 
  
ECFF15Tractor Implement Management (TIM) Server(Byte 1) Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFFDetails →
ECFF16Tractor Implement Management (TIM) Client(Byte 1) Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFFDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 1) 0 to 255Number of control channelsDetails →
CFF10Task Controller Geo (TC-GEO) Client(Byte 1) 0 to 255Number of control channelsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0000No optionsDetails →
CFF1Universal Terminal (UT) Server(Byte 1) 0000 0000No optionsDetails →
CFF2Universal Terminal (UT) Client(Byte 1) 0000 0000No optionsDetails →
CFF3Aux-O inputs(Byte 1) 0000 0000No optionsDetails →
CFF4Aux-O functions(Byte 1) 0000 0000No optionsDetails →
CFF5Aux-N inputs(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF17File Server(Byte 1) 0000 0000No optionsDetails →
CFF18File Server Client(Byte 1) 0000 0000No optionsDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) 0000 0000No optionsDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) 0000 0000No optionsDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) 0000 0000No optionsDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) 0000 0000No optionsDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) 0000 0000No optionsDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) 0000 0000No optionsDetails →
CFF25Datalogger (LOG) Client(Byte 1) 0000 0000No optionsDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0001Aux valve 1 state is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0001Type I ECU – Internal weak termination Details →
CFF3Aux-O inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0001Data logger (LOG) service type supports FMIS interfaceDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0001Aux valve 1 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0010Aux valve 1 flow is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0010Type II ECU – Internal end-point terminationDetails →
CFF3Aux-O inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0010Aux valve 1 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0100Aux valve 2 state is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0100Support of Heartbeat producerDetails →
CFF3Aux-O inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF4Aux-O functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0100Lighting option (L)Details →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0100Class required lighting (L)Details →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0100Aux valve 2 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 1000Aux valve 2 flow is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 1000Support of Heartbeat consumerDetails →
CFF5Aux-N inputs(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 1000Navigation option (N)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 1000Navigation option (N)Details →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 1000Aux valve 2 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0001 0000Aux valve 3 state is supportedDetails →
CFF5Aux-N inputs(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF6Aux-N functions(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0001 0000Front hitch option (F)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0001 0000Front hitch option (F)Details →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0001 0000Aux valve 3 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0010 0000Aux valve 3 flow is supportedDetails →
CFF5Aux-N inputs(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF6Aux-N functions(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0010 0000Guidance option (G)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0010 0000Guidance option (G)Details →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0010 0000Aux valve 3 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0100 0000Aux valve 4 state is supportedDetails →
CFF5Aux-N inputs(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF6Aux-N functions(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0100 0000Aux valve 4 state is supportedDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 1) 1 to 255Number of supported boomsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 1) 1 to 255Number of supported boomsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 1000 0000Aux valve 4 flow is supportedDetails →
CFF5Aux-N inputs(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF6Aux-N functions(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 1000 0000Aux valve 4 flow is supportedDetails →
CFF1Universal Terminal (UT) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF2Universal Terminal (UT) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →