Displaying 201-300 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 1 - 00110000Aux Valve N (N = 1 to 32) flow support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 2 - 11000000Aux Valve N (N = 1 to 32) valve upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 2 - 00001100Aux Valve N (N = 1 to 32) valve function aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 11000000PTO disengagement support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 00110000PTO engagement counter-clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 00001100PTO engagement clockwise support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 1 - 00000011PTO speed counter-clockwise support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 2 - 11000000PTO speed clockwise support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0001Aux valve 1 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 3 - 11000000PTO upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0010Aux valve 1 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4016 Front PTO - FacOptByte 3 - 00001100PTO function aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0100Aux valve 2 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 11000000PTO disengagement support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 1000Aux valve 2 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 00110000PTO engagement counter-clockwise support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0001 0000Aux valve 3 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 00001100PTO engagement clockwise support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0010 0000Aux valve 3 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 1 - 00000011PTO speed counter-clockwise support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0100 0000Aux valve 4 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 2 - 11000000PTO speed clockwise support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 1000 0000Aux valve 4 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 3 - 11000000PTO upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4116 Rear PTO - FacOptByte 3 - 00001100PTO function aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0001Aux valve 5 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 1 - 11000000Front Hitch motion (raise/lower/float/stop) support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0010Aux valve 5 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 1 - 00110000Front Hitch position support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0100Aux valve 6 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 2 - 11000000Front Hitch upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 1000Aux valve 6 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 2 - 00001100Front Hitch aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0001 0000Aux valve 7 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 1 - 11000000Rear Hitch motion (raise/lower/float/stop) support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0010 0000Aux valve 7 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 1 - 00110000Rear Hitch position support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0100 0000Aux valve 8 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 2 - 11000000Rear Hitch upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 1000 0000Aux valve 8 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4316 Rear Hitch - FacOptByte 2 - 00001100Rear Hitch aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0000No options for this option byte supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 11000000Vehicle Speed while driving in forward direction support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0001Aux valve 9 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 00110000Vehicle Speed while driving in reverse direction support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0010Aux valve 9 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 00001100Start vehicle motion support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0100Aux valve 10 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 1 - 00000011Stop vehicle motion support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 1000Aux valve 10 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 2 - 11000000Forward direction, speed set by TIM server support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0001 0000Aux valve 11 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 2 - 00110000Reverse direction, speed set by TIM server support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0010 0000Aux valve 11 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 3 - 11000000Vehicle speed upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0100 0000Aux valve 12 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 3 - 00001100Vehicle speed aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 1000 0000Aux valve 12 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 1 - 11000000Curvature support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0000No options for this option byte supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 2 - 11000000External Guidance upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0001Aux valve 13 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 2 - 00001100External Guidance aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0010Aux valve 13 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 1 - 11000000Front Top linkage motion (extend/retract/float/stop) support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0100Aux valve 14 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 1 - 00110000Front Top linkage position support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 1000Aux valve 14 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 2 - 11000000Front Top linkage upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0001 0000Aux valve 15 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 2 - 00001100Front Top linkage aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0010 0000Aux valve 15 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 1 - 11000000Rear Top linkage motion (extend/retract/float/stop) support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0100 0000Aux valve 16 state is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 1 - 00110000Rear Top linkage position support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 1000 0000Aux valve 16 flow is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 2 - 11000000Rear Top linkage upper limit handling support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0000No options for this option byte supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 2 - 00001100Rear Top linkage aggressiveness support indicationDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0001Aux valve 17 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0010Aux valve 17 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0100Aux valve 18 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 1000Aux valve 18 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0001 0000Aux valve 19 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0010 0000Aux valve 19 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0100 0000Aux valve 20 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 1000 0000Aux valve 20 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0001Aux valve 21 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0010Aux valve 21 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0100Aux valve 22 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 1000Aux valve 22 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0001 0000Aux valve 23 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0010 0000Aux valve 23 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0100 0000Aux valve 24 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 1000 0000Aux valve 24 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0001Aux valve 25 state is supportedDetails →