Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 1-100 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF25Datalogger (LOG) Client(Byte 1) 0000 0000No optionsDetails →
CFF25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0001Data logger (LOG) service type supports FMIS interfaceDetails →
CFF24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) 0000 0000No optionsDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) 0000 0000No optionsDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) 0000 0000No optionsDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) 0000 0000No optionsDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF18File Server Client(Byte 1) 0000 0000No optionsDetails →
CFF18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF17File Server(Byte 1) 0000 0000No optionsDetails →
CFF17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0001Aux valve 1 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0010Aux valve 1 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0100Aux valve 2 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 1000Aux valve 2 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0001 0000Aux valve 3 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0010 0000Aux valve 3 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0100 0000Aux valve 4 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 1000 0000Aux valve 4 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0001Aux valve 5 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0010Aux valve 5 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0100Aux valve 6 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 1000Aux valve 6 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0001 0000Aux valve 7 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0010 0000Aux valve 7 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0100 0000Aux valve 8 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 1000 0000Aux valve 8 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0001Aux valve 9 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0010Aux valve 9 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0100Aux valve 10 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 1000Aux valve 10 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0001 0000Aux valve 11 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0010 0000Aux valve 11 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0100 0000Aux valve 12 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 1000 0000Aux valve 12 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0001Aux valve 13 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0010Aux valve 13 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0100Aux valve 14 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 1000Aux valve 14 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0001 0000Aux valve 15 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0010 0000Aux valve 15 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0100 0000Aux valve 16 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 1000 0000Aux valve 16 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0001Aux valve 17 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0010Aux valve 17 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0100Aux valve 18 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 1000Aux valve 18 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0001 0000Aux valve 19 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0010 0000Aux valve 19 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0100 0000Aux valve 20 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 1000 0000Aux valve 20 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0001Aux valve 21 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0010Aux valve 21 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0100Aux valve 22 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 1000Aux valve 22 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0001 0000Aux valve 23 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0010 0000Aux valve 23 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0100 0000Aux valve 24 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 1000 0000Aux valve 24 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0001Aux valve 25 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0010Aux valve 25 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0100Aux valve 26 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 1000Aux valve 26 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0001 0000Aux valve 27 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0010 0000Aux valve 27 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0100 0000Aux valve 28 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 1000 0000Aux valve 28 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0001Aux valve 29 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0010Aux valve 29 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0100Aux valve 30 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 1000Aux valve 30 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0001 0000Aux valve 31 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0010 0000Aux valve 31 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0100 0000Aux valve 32 state is supportedDetails →