Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 201-300 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF5Aux-N inputs(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 13) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 14) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 15) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) 0000 0000No options for this option byte supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0000No optionsDetails →
CFF1Universal Terminal (UT) Server(Byte 1) 0000 0000No optionsDetails →
CFF2Universal Terminal (UT) Client(Byte 1) 0000 0000No optionsDetails →
CFF3Aux-O inputs(Byte 1) 0000 0000No optionsDetails →
CFF4Aux-O functions(Byte 1) 0000 0000No optionsDetails →
CFF17File Server(Byte 1) 0000 0000No optionsDetails →
CFF18File Server Client(Byte 1) 0000 0000No optionsDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) 0000 0000No optionsDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) 0000 0000No optionsDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) 0000 0000No optionsDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) 0000 0000No optionsDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) 0000 0000No optionsDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) 0000 0000No optionsDetails →
CFF25Datalogger (LOG) Client(Byte 1) 0000 0000No optionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 1000Navigation option (N)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 1000Navigation option (N)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0100Lighting option (L)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0010 0000Guidance option (G)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0010 0000Guidance option (G)Details →
CFF15Tractor Implement Management (TIM) Server(Byte 15) 0000 0001Guidance curvature is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 15) 0000 0001Guidance curvature is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 2 - 11000000Front Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 2 - 11000000Front Top linkage upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 1 - 00110000Front Top linkage position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 1 - 00110000Front Top linkage position support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 1 - 11000000Front Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 1 - 11000000Front Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage config, bits 4 to 1Front Top Linkage config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 2 - 00001100Front Top linkage aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 2 - 00001100Front Top linkage aggressiveness support indicationDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0001 0000Front PTO speed CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0001 0000Front PTO speed CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 1000Front PTO speed CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 1000Front PTO speed CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0100Front PTO engagement CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0100Front PTO engagement CW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0010Front PTO engagement CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0010Front PTO engagement CCW is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0001Front PTO disengagement is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0001Front PTO disengagement is supportedDetails →
ECFF16Tractor Implement Management (TIM) Client4016 Front PTO config, bits 4 to 1Front PTO config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 2 - 11000000Front Hitch upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4216 Front Hitch - FacOptByte 2 - 11000000Front Hitch upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 1 - 00110000Front Hitch position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4216 Front Hitch - FacOptByte 1 - 00110000Front Hitch position support indicationDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 12) 0000 0010Front hitch position is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0010Front hitch position is supportedDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0001 0000Front hitch option (F)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0001 0000Front hitch option (F)Details →
CFF16Tractor Implement Management (TIM) Client(Byte 12) 0000 0001Front hitch motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0001Front hitch motion is supportedDetails →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 1 - 11000000Front Hitch motion (raise/lower/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4216 Front Hitch - FacOptByte 1 - 11000000Front Hitch motion (raise/lower/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4216 Front Hitch config, bits 4 to 1Front Hitch config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4216 Front Hitch - FacOptByte 2 - 00001100Front Hitch aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4216 Front Hitch - FacOptByte 2 - 00001100Front Hitch aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4416 Vehicle Speed - FacOptByte 2 - 11000000Forward direction, speed set by TIM server support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed - FacOptByte 2 - 11000000Forward direction, speed set by TIM server support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 2 - 11000000External Guidance upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance - FacOptByte 2 - 11000000External Guidance upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance config, bits 4 to 1External Guidance config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 2 - 00001100External Guidance aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance - FacOptByte 2 - 00001100External Guidance aggressiveness support indicationDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0001Data logger (LOG) service type supports FMIS interfaceDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 1 - 11000000Curvature support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance - FacOptByte 1 - 11000000Curvature support indicationDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0100Class required lighting (L)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0001Class 1, no optionsDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 2 - 11000000Aux Valve N (N = 1 to 32) valve upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 2 - 00001100Aux Valve N (N = 1 to 32) valve function aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) ClientAux Valve N - FacOptByte 2 - 11000000Aux Valve N (N = 1 to 32) upper limit handling support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 1 - 11000000Aux Valve N (N = 1 to 32) state support indicationDetails →