| CFF / ECFF | Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|---|
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 7) 0001 0000 | Aux valve 27 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 7) 0010 0000 | Aux valve 27 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 7) 0100 0000 | Aux valve 28 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 7) 1000 0000 | Aux valve 28 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0000 0001 | Aux valve 29 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0000 0010 | Aux valve 29 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0000 0100 | Aux valve 30 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0000 1000 | Aux valve 30 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0001 0000 | Aux valve 31 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0010 0000 | Aux valve 31 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 0100 0000 | Aux valve 32 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 8) 1000 0000 | Aux valve 32 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 9) bits 1 to 6, values 0 to 32 | Amount of supported auxiliary valves | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 9) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0001 | Front PTO disengagement is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0010 | Front PTO engagement CCW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 0100 | Front PTO engagement CW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0000 1000 | Front PTO speed CCW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) 0001 0000 | Front PTO speed CW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 10) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 0001 | Rear PTO disengagement is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 0010 | Rear PTO engagement CCW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 0100 | Rear PTO engagement CW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0000 1000 | Rear PTO speed CCW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0001 | Front hitch motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0010 | Front hitch position is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0001 | Rear hitch motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0010 | Rear hitch position is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 1000 0000 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0001 | Guidance curvature is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 1) | Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFF | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) | Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3 +) - TIM Option Byte Structure Definition | TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b, bits 4 to 1) TIM function ID config 0x0 - Optional 0x1 - Required 0x2 to 0xF - Reserved - (Byte c) Number of Facility Option Bytes (FacOptByte) to follow - (Byte d +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve #Count 1 to 32 (how many valves used by TIM client) 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N config, bits 4 to 1 | Aux Valve N (N = 1 to 32) config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 1 - 11000000 | Aux Valve N (N = 1 to 32) state support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 1 - 00110000 | Aux Valve N (N = 1 to 32) flow support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 2 - 11000000 | Aux Valve N (N = 1 to 32) upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | Aux Valve N - FacOptByte 2 - 00001100 | Aux Valve N (N = 1 to 32) aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO config, bits 4 to 1 | Front PTO config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 1 - 11000000 | PTO disengagement support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 1 - 00110000 | PTO engagement counter-clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 1 - 00001100 | PTO engagement clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 1 - 00000011 | PTO speed counter-clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 2 - 11000000 | PTO speed clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 3 - 11000000 | PTO upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4016 Front PTO - FacOptByte 3 - 00001100 | PTO function aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO config, bits 4 to 1 | Rear PTO config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 1 - 11000000 | PTO disengagement support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 1 - 00110000 | PTO engagement counter-clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 1 - 00001100 | PTO engagement clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 1 - 00000011 | PTO speed counter-clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 2 - 11000000 | PTO speed clockwise support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 3 - 11000000 | PTO upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4116 Rear PTO - FacOptByte 3 - 00001100 | PTO function aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch config, bits 4 to 1 | Front Hitch config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 1 - 11000000 | Front Hitch motion (raise/lower/float/stop) support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 1 - 00110000 | Front Hitch position support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 2 - 11000000 | Front Hitch upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4216 Front Hitch - FacOptByte 2 - 00001100 | Front Hitch aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4316 Rear Hitch config, bits 4 to 1 | Rear Hitch config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4316 Rear Hitch - FacOptByte 1 - 11000000 | Rear Hitch motion (raise/lower/float/stop) support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4316 Rear Hitch - FacOptByte 1 - 00110000 | Rear Hitch position support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4316 Rear Hitch - FacOptByte 2 - 11000000 | Rear Hitch upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4316 Rear Hitch - FacOptByte 2 - 00001100 | Rear Hitch aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed config, bits 4 to 1 | Vehicle Speed config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 11000000 | Vehicle Speed while driving in forward direction support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 00110000 | Vehicle Speed while driving in reverse direction support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 00001100 | Start vehicle motion support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 1 - 00000011 | Stop vehicle motion support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 2 - 11000000 | Forward direction, speed set by TIM server support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 2 - 00110000 | Reverse direction, speed set by TIM server support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 3 - 11000000 | Vehicle speed upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4416 Vehicle Speed - FacOptByte 3 - 00001100 | Vehicle speed aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance config, bits 4 to 1 | External Guidance config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance - FacOptByte 1 - 11000000 | Curvature support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance - FacOptByte 2 - 11000000 | External Guidance upper limit handling support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4616 External Guidance - FacOptByte 2 - 00001100 | External Guidance aggressiveness support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage config, bits 4 to 1 | Front Top Linkage config (0x0 optional, 0x1 required) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 1 - 11000000 | Front Top linkage motion (extend/retract/float/stop) support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 1 - 00110000 | Front Top linkage position support indication | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | 4716 Front top linkage - FacOptByte 2 - 11000000 | Front Top linkage upper limit handling support indication | Details → |