Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 1-100 of 435 results.
| CFF / ECFF | Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|---|
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0001 | Type I ECU – Internal weak termination | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0010 | Type II ECU – Internal end-point termination | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 0100 | Support of Heartbeat producer | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) 0000 1000 | Support of Heartbeat consumer | Details → |
| CFF | 0 | Minimum Control Function | (Byte 1) bits 5 to 8 | Reserved for ISO assignment | Details → |
| CFF | 1 | Universal Terminal (UT) Server | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 1 | Universal Terminal (UT) Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 2 | Universal Terminal (UT) Client | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 2 | Universal Terminal (UT) Client | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 3 | Aux-O inputs | (Byte 1) bits 4 to 8 | Reserved for ISO assignment | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 4 | Aux-O functions | (Byte 1) bits 4 to 8 | Reserved for ISO assignment | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 1000 | Supports type 3 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0001 0000 | Supports type 4 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0010 0000 | Supports type 5 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0100 0000 | Supports type 6 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 1000 0000 | Supports type 7 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) bit 8 | Reserved for ISO assignment | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 1000 | Supports type 3 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0001 0000 | Supports type 4 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0010 0000 | Supports type 5 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0100 0000 | Supports type 6 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 1000 0000 | Supports type 7 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) bit 8 | Reserved for ISO assignment | Details → |
| CFF | 7 | Task Controller Basic (TC-BAS) Server | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 7 | Task Controller Basic (TC-BAS) Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 8 | Task Controller Basic (TC-BAS) Client | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 8 | Task Controller Basic (TC-BAS) Client | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 1) 0 to 255 | Number of control channels | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0001 | Polygon-based prescription maps are supported | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 10 | Task Controller Geo (TC-GEO) Client | (Byte 1) 0 to 255 | Number of control channels | Details → |
| CFF | 11 | Task Controller Section Control (TC-SC) Server | (Byte 1) 1 to 255 | Number of supported booms | Details → |
| CFF | 11 | Task Controller Section Control (TC-SC) Server | (Byte 2) 1 to 255 | Number of supported sections | Details → |
| CFF | 12 | Task Controller Section Control (TC-SC) Client | (Byte 1) 1 to 255 | Number of supported booms | Details → |
| CFF | 12 | Task Controller Section Control (TC-SC) Client | (Byte 2) 1 to 255 | Number of supported sections | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0000 | TECU not meeting complete class 1 requirements | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0001 | Class 1, no options | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0010 | Class 2, no options | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0100 | Lighting option (L) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 1000 | Navigation option (N) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0001 0000 | Front hitch option (F) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0010 0000 | Guidance option (G) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0000 | TECU not meeting complete class 1 requirements | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0001 | Class 1, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0010 | Class 2, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0100 | Class required lighting (L) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 1000 | Navigation option (N) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0001 0000 | Front hitch option (F) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0010 0000 | Guidance option (G) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0001 | Guidance curvature is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 1) | Version of Option Byte Structure 0016 - 1st version of TIM Option Bytes for ECFF | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) | Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3 +) - TIM Option Byte Structure Definition | TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b) Number of Facility Option Bytes (FacOptByte) to follow - (Byte c +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve 1 to 32 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1) | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 1 - 11000000 | Aux Valve N (N = 1 to 32) state support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 1 - 00110000 | Aux Valve N (N = 1 to 32) flow support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 2 - 11000000 | Aux Valve N (N = 1 to 32) valve upper limit handling support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | Aux Valve N - FacOptByte 2 - 00001100 | Aux Valve N (N = 1 to 32) valve function aggressiveness support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4016 Front PTO - FacOptByte 1 - 11000000 | PTO disengagement support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4016 Front PTO - FacOptByte 1 - 00110000 | PTO engagement counter-clockwise support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4016 Front PTO - FacOptByte 1 - 00001100 | PTO engagement clockwise support indication | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4016 Front PTO - FacOptByte 1 - 00000011 | PTO speed counter-clockwise support indication | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 1) 0000 0000 | No options for this option byte supported | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | 4016 Front PTO - FacOptByte 2 - 11000000 | PTO speed clockwise support indication | Details → |