| CFF / ECFF | Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|---|
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 0010 | Aux valve 25 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 0100 | Aux valve 26 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0000 1000 | Aux valve 26 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0001 0000 | Aux valve 27 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0010 0000 | Aux valve 27 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 0100 0000 | Aux valve 28 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 7) 1000 0000 | Aux valve 28 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0001 | Aux valve 29 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0010 | Aux valve 29 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 0100 | Aux valve 30 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0000 1000 | Aux valve 30 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0001 0000 | Aux valve 31 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0010 0000 | Aux valve 31 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 0100 0000 | Aux valve 32 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 8) 1000 0000 | Aux valve 32 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 9) bits 1 to 6, values 0 to 32 | Amount of supported auxiliary valves | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 9) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0001 | Front PTO disengagement is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0010 | Front PTO engagement CCW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 0100 | Front PTO engagement CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0000 1000 | Front PTO speed CCW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) 0001 0000 | Front PTO speed CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 10) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0001 | Rear PTO disengagement is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0010 | Rear PTO engagement CCW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 0100 | Rear PTO engagement CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0000 1000 | Rear PTO speed CCW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0001 | Front hitch motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0010 | Front hitch position is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0001 | Rear hitch motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0010 | Rear hitch position is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 1000 0000 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0000 | TECU not meeting complete class 1 requirements | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0001 | Class 1, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0010 | Class 2, no options | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 0100 | Class required lighting (L) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0000 1000 | Navigation option (N) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0001 0000 | Front hitch option (F) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) 0010 0000 | Guidance option (G) | Details → |
| CFF | 14 | Basic Tractor ECU (TECU) Client | (Byte 1) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0000 | TECU not meeting complete class 1 requirements | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0001 | Class 1, no options | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0010 | Class 2, no options | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 0100 | Lighting option (L) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0000 1000 | Navigation option (N) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0001 0000 | Front hitch option (F) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) 0010 0000 | Guidance option (G) | Details → |
| CFF | 13 | Basic Tractor ECU (TECU) Server | (Byte 1) bits 7 to 8 | Reserved for ISO assignment | Details → |
| CFF | 12 | Task Controller Section Control (TC-SC) Client | (Byte 1) 1 to 255 | Number of supported booms | Details → |
| CFF | 12 | Task Controller Section Control (TC-SC) Client | (Byte 2) 1 to 255 | Number of supported sections | Details → |
| CFF | 11 | Task Controller Section Control (TC-SC) Server | (Byte 1) 1 to 255 | Number of supported booms | Details → |
| CFF | 11 | Task Controller Section Control (TC-SC) Server | (Byte 2) 1 to 255 | Number of supported sections | Details → |
| CFF | 10 | Task Controller Geo (TC-GEO) Client | (Byte 1) 0 to 255 | Number of control channels | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 1) 0 to 255 | Number of control channels | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0001 | Polygon-based prescription maps are supported | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 8 | Task Controller Basic (TC-BAS) Client | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 8 | Task Controller Basic (TC-BAS) Client | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 7 | Task Controller Basic (TC-BAS) Server | (Byte 1) 0000 0000 | No options | Details → |
| CFF | 7 | Task Controller Basic (TC-BAS) Server | (Byte 1) bits 1 to 8 | Reserved for ISO assignment | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0010 | Supports type 1 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 0100 | Supports type 2 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0000 1000 | Supports type 3 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0001 0000 | Supports type 4 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0010 0000 | Supports type 5 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 0100 0000 | Supports type 6 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 1) 1000 0000 | Supports type 7 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) bit 8 | Reserved for ISO assignment | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0001 | Supports type 0 function | Details → |
| CFF | 5 | Aux-N inputs | (Byte 1) 0000 0010 | Supports type 1 function | Details → |