CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0010Aux valve 25 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0100Aux valve 26 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 1000Aux valve 26 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0001 0000Aux valve 27 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0010 0000Aux valve 27 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0100 0000Aux valve 28 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 1000 0000Aux valve 28 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0000 0001Aux valve 29 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0000 0010Aux valve 29 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0000 0100Aux valve 30 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0000 1000Aux valve 30 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0001 0000Aux valve 31 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0010 0000Aux valve 31 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 0100 0000Aux valve 32 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 8) 1000 0000Aux valve 32 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 9) bits 1 to 6, values 0 to 32Amount of supported auxiliary valvesDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 9) bits 7 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0001Front PTO disengagement is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0010Front PTO engagement CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 0100Front PTO engagement CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0000 1000Front PTO speed CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) 0001 0000Front PTO speed CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 10) bits 6 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0001Rear PTO disengagement is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0010Rear PTO engagement CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 0100Rear PTO engagement CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0000 1000Rear PTO speed CCW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) 0001 0000Rear PTO speed CW is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 11) bits 6 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0001Front hitch motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) 0000 0010Front hitch position is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 12) bits 3 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0001Rear hitch motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) 0000 0010Rear hitch position is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 13) bits 3 to 8Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0001Vehicle Speed in forward direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0010Vehicle Speed in reverse direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 0100Vehicle Speed start motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0000 1000Vehicle Speed stop motion is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0001 0000Vehicle Speed forward set by server is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0010 0000Vehicle Speed reverse set by server is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 0100 0000Vehicle Speed change direction is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 14) 1000 0000Reserved for ISO assignmentDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) 0000 0000No options for this option byte supportedDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 0100Class required lighting (L)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0000 1000Navigation option (N)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0001 0000Front hitch option (F)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) 0010 0000Guidance option (G)Details →
CFF14Basic Tractor ECU (TECU) Client(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0000TECU not meeting complete class 1 requirementsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0001Class 1, no optionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0010Class 2, no optionsDetails →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 0100Lighting option (L)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0000 1000Navigation option (N)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0001 0000Front hitch option (F)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) 0010 0000Guidance option (G)Details →
CFF13Basic Tractor ECU (TECU) Server(Byte 1) bits 7 to 8Reserved for ISO assignmentDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 1) 1 to 255Number of supported boomsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 1) 1 to 255Number of supported boomsDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF10Task Controller Geo (TC-GEO) Client(Byte 1) 0 to 255Number of control channelsDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 1) 0 to 255Number of control channelsDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) 0000 0001Polygon-based prescription maps are supportedDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) bits 2 to 8Reserved for ISO assignmentDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) 0000 0000No optionsDetails →
CFF8Task Controller Basic (TC-BAS) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) 0000 0000No optionsDetails →
CFF7Task Controller Basic (TC-BAS) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF6Aux-N functions(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF6Aux-N functions(Byte 1) 0000 1000Supports type 3 functionDetails →
CFF6Aux-N functions(Byte 1) 0001 0000Supports type 4 functionDetails →
CFF6Aux-N functions(Byte 1) 0010 0000Supports type 5 functionDetails →
CFF6Aux-N functions(Byte 1) 0100 0000Supports type 6 functionDetails →
CFF6Aux-N functions(Byte 1) 1000 0000Supports type 7 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF6Aux-N functions(Byte 2) 0000 0001Supports type 8 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0010Supports type 9 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 0100Supports type 10 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF6Aux-N functions(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF6Aux-N functions(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF6Aux-N functions(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF6Aux-N functions(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF5Aux-N inputs(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF5Aux-N inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF5Aux-N inputs(Byte 1) 0000 0010Supports type 1 functionDetails →