Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 401-435 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 2 - 00001100Front Top linkage aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage config, bits 4 to 1Rear Top Linkage config (0x0 optional, 0x1 required)Details →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 1 - 11000000Rear Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 1 - 00110000Rear Top linkage position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 2 - 11000000Rear Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 2 - 00001100Rear Top linkage aggressiveness support indicationDetails →
CFF17File Server(Byte 1) 0000 0000No optionsDetails →
CFF17File Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF18File Server Client(Byte 1) 0000 0000No optionsDetails →
CFF18File Server Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) 0000 0000No optionsDetails →
CFF19Sequence Controller (SQC) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) 0000 0000No optionsDetails →
CFF20Sequence Controller (SQC) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) 0000 0000No optionsDetails →
CFF21ISOBUS Shortcut Button (ISB) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) 0000 0000No optionsDetails →
CFF22ISOBUS Shortcut Button (ISB) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF24Datalogger (LOG) Server(Byte 1) 0000 0001Data logger (LOG) service type supports FMIS interfaceDetails →
CFF24Datalogger (LOG) Server(Byte 1) bits 2 to 8Reserved for ISO assignmentDetails →
CFF25Datalogger (LOG) Client(Byte 1) 0000 0000No optionsDetails →
CFF25Datalogger (LOG) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0001Support of onboard visualizationDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0010Support of diagnostic data exportDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) 0000 0100Support of CAN trace possibilityDetails →
CFF26ISOBUS System Information (INFO) Server(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF27Task Controller Tramline (TRACK) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0001Tramline rythm transitionDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0010Storage of implement track parametersDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) 0000 0100Tramline controlDetails →
CFF28Task Controller Tramline (TRACK) Client(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →