Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 401-435 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
ECFF16Tractor Implement Management (TIM) Client4416 Vehicle Speed config, bits 4 to 1Vehicle Speed config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 1 - 11000000Curvature support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance - FacOptByte 1 - 11000000Curvature support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 2 - 00001100External Guidance aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance - FacOptByte 2 - 00001100External Guidance aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4616 External Guidance - FacOptByte 2 - 11000000External Guidance upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance - FacOptByte 2 - 11000000External Guidance upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4616 External Guidance config, bits 4 to 1External Guidance config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 1 - 00110000Front Top linkage position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 1 - 00110000Front Top linkage position support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 1 - 11000000Front Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 1 - 11000000Front Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 2 - 00001100Front Top linkage aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 2 - 00001100Front Top linkage aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4716 Front top linkage - FacOptByte 2 - 11000000Front Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage - FacOptByte 2 - 11000000Front Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4716 Front top linkage config, bits 4 to 1Front Top Linkage config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 1 - 00110000Rear Top linkage position support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 1 - 00110000Rear Top linkage position support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 1 - 11000000Rear Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 1 - 11000000Rear Top linkage motion (extend/retract/float/stop) support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 2 - 00001100Rear Top linkage aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 2 - 00001100Rear Top linkage aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) Server4816 Rear top linkage - FacOptByte 2 - 11000000Rear Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage - FacOptByte 2 - 11000000Rear Top linkage upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) Client4816 Rear top linkage config, bits 4 to 1Rear Top Linkage config (0x0 optional, 0x1 required)Details →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 1 - 00110000Aux Valve N (N = 1 to 32) flow support indicationDetails →
ECFF16Tractor Implement Management (TIM) ClientAux Valve N - FacOptByte 1 - 00110000Aux Valve N (N = 1 to 32) flow support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 1 - 11000000Aux Valve N (N = 1 to 32) state support indicationDetails →
ECFF16Tractor Implement Management (TIM) ClientAux Valve N - FacOptByte 1 - 11000000Aux Valve N (N = 1 to 32) state support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 2 - 00001100Aux Valve N (N = 1 to 32) valve function aggressiveness support indicationDetails →
ECFF16Tractor Implement Management (TIM) ClientAux Valve N - FacOptByte 2 - 00001100Aux Valve N (N = 1 to 32) aggressiveness support indicationDetails →
ECFF15Tractor Implement Management (TIM) ServerAux Valve N - FacOptByte 2 - 11000000Aux Valve N (N = 1 to 32) valve upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) ClientAux Valve N - FacOptByte 2 - 11000000Aux Valve N (N = 1 to 32) upper limit handling support indicationDetails →
ECFF16Tractor Implement Management (TIM) ClientAux Valve N config, bits 4 to 1Aux Valve N (N = 1 to 32) config (0x0 optional, 0x1 required)Details →