Attention: You are working on the beta server! Any changes made to the database will be reverted upon the next update!

Functionality and Option

To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <> or =) at the beginning of each of your search values to specify how the comparison should be done.

Advanced Search
Displaying 201-300 of 435 results.
CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF5Aux-N inputs(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF6Aux-N functions(Byte 2) 0000 1000Supports type 11 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0000 1000Aux valve 6 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0001 0000Aux valve 7 state is supportedDetails →
CFF5Aux-N inputs(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF6Aux-N functions(Byte 2) 0001 0000Supports type 12 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0001 0000Aux valve 7 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0010 0000Aux valve 7 flow is supportedDetails →
CFF5Aux-N inputs(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF6Aux-N functions(Byte 2) 0010 0000Supports type 13 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0010 0000Aux valve 7 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0100 0000Aux valve 8 state is supportedDetails →
CFF5Aux-N inputs(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF6Aux-N functions(Byte 2) 0100 0000Supports type 14 functionDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 0100 0000Aux valve 8 state is supportedDetails →
CFF11Task Controller Section Control (TC-SC) Server(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF12Task Controller Section Control (TC-SC) Client(Byte 2) 1 to 255Number of supported sectionsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 1000 0000Aux valve 8 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 2) 1000 0000Aux valve 8 flow is supportedDetails →
CFF5Aux-N inputs(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF6Aux-N functions(Byte 2) bit 8Reserved for ISO assignmentDetails →
CFF9Task Controller Geo (TC-GEO) Server(Byte 2) bits 2 to 8Reserved for ISO assignmentDetails →
ECFF15Tractor Implement Management (TIM) Server(Byte 3 +) - TIM Option Byte Structure DefinitionTIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b) Number of Facility Option Bytes (FacOptByte) to follow - (Byte c +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve 1 to 32 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1)Details →
ECFF16Tractor Implement Management (TIM) Client(Byte 3 +) - TIM Option Byte Structure Definition TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b, bits 4 to 1) TIM function ID config 0x0 - Optional 0x1 - Required 0x2 to 0xF - Reserved - (Byte c) Number of Facility Option Bytes (FacOptByte) to follow - (Byte d +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve #Count 1 to 32 (how many valves used by TIM client) 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1)Details →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0001Aux valve 9 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0001Aux valve 9 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0010Aux valve 9 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0010Aux valve 9 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0100Aux valve 10 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 0100Aux valve 10 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 1000Aux valve 10 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0000 1000Aux valve 10 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0001 0000Aux valve 11 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0001 0000Aux valve 11 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0010 0000Aux valve 11 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0010 0000Aux valve 11 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0100 0000Aux valve 12 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 0100 0000Aux valve 12 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 1000 0000Aux valve 12 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 3) 1000 0000Aux valve 12 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0001Aux valve 13 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0001Aux valve 13 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0010Aux valve 13 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0010Aux valve 13 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0100Aux valve 14 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 0100Aux valve 14 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 1000Aux valve 14 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0000 1000Aux valve 14 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0001 0000Aux valve 15 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0001 0000Aux valve 15 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0010 0000Aux valve 15 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0010 0000Aux valve 15 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0100 0000Aux valve 16 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 0100 0000Aux valve 16 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 1000 0000Aux valve 16 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 4) 1000 0000Aux valve 16 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0001Aux valve 17 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0001Aux valve 17 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0010Aux valve 17 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0010Aux valve 17 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0100Aux valve 18 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 0100Aux valve 18 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 1000Aux valve 18 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0000 1000Aux valve 18 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0001 0000Aux valve 19 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0001 0000Aux valve 19 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0010 0000Aux valve 19 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0010 0000Aux valve 19 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0100 0000Aux valve 20 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 0100 0000Aux valve 20 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 1000 0000Aux valve 20 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 5) 1000 0000Aux valve 20 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0001Aux valve 21 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0001Aux valve 21 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0010Aux valve 21 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0010Aux valve 21 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0100Aux valve 22 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 0100Aux valve 22 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 1000Aux valve 22 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0000 1000Aux valve 22 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0001 0000Aux valve 23 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0001 0000Aux valve 23 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0010 0000Aux valve 23 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0010 0000Aux valve 23 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0100 0000Aux valve 24 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 0100 0000Aux valve 24 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 1000 0000Aux valve 24 flow is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 6) 1000 0000Aux valve 24 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0001Aux valve 25 state is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 7) 0000 0001Aux valve 25 state is supportedDetails →