| CFF / ECFF | Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|---|
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0001 0000 | Aux valve 11 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 1000 | Aux valve 10 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 1000 | Aux valve 10 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0100 | Aux valve 10 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0100 | Aux valve 10 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0010 | Aux valve 9 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0001 | Aux valve 9 state is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0001 | Aux valve 9 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3) 0000 0000 | No options for this option byte supported | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 3 +) - TIM Option Byte Structure Definition | TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b) Number of Facility Option Bytes (FacOptByte) to follow - (Byte c +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve 1 to 32 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 3 +) - TIM Option Byte Structure Definition | TIM Option Byte Structure consist of: - (Byte a) TIM function ID (see below) - (Byte b, bits 4 to 1) TIM function ID config 0x0 - Optional 0x1 - Required 0x2 to 0xF - Reserved - (Byte c) Number of Facility Option Bytes (FacOptByte) to follow - (Byte d +) 1 to n Facility Option Bytes for the TIM Function ID Each 2 bit facility indication uses one of the following values: 002 - Server/Client does not support this facility 012 - Server/Client supports this facility 102 - Reserved 112 - The facility was not defined when the Server was built List of AEF TIM Function IDs: 0116 to 2016 Auxiliary Valve #Count 1 to 32 (how many valves used by TIM client) 4016 Front PTO 4116 Rear PTO 4216 Front Hitch 4316 Rear Hitch 4416 Vehicle Speed 4616 External Guidance 4716 Front top linkage (not applicable for TIM gen1) 4816 Rear top linkage (not applicable for TIM gen1) | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) bit 8 | Reserved for ISO assignment | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) bit 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 1000 0000 | Aux valve 8 flow is supported | Details → |
| CFF | 11 | Task Controller Section Control (TC-SC) Server | (Byte 2) 1 to 255 | Number of supported sections | Details → |
| CFF | 12 | Task Controller Section Control (TC-SC) Client | (Byte 2) 1 to 255 | Number of supported sections | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0100 0000 | Aux valve 8 state is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0100 0000 | Supports type 14 function | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0100 0000 | Aux valve 8 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0010 0000 | Supports type 13 function | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0010 0000 | Aux valve 7 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0001 0000 | Aux valve 7 state is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0001 0000 | Supports type 12 function | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0001 0000 | Aux valve 7 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 1000 | Aux valve 6 flow is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 1000 | Supports type 11 function | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 1000 | Aux valve 6 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0100 | Aux valve 6 state is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0100 | Supports type 10 function | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0100 | Aux valve 6 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0010 | Aux valve 5 flow is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0010 | Supports type 9 function | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0010 | Aux valve 5 flow is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0001 | Aux valve 5 state is supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0001 | Supports type 8 function | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0001 | Polygon-based prescription maps are supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0001 | Aux valve 5 state is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 5 | Aux-N inputs | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 6 | Aux-N functions | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 9 | Task Controller Geo (TC-GEO) Server | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) 0000 0000 | No options for this option byte supported | Details → |
| ECFF | 15 | Tractor Implement Management (TIM) Server | (Byte 2) | Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240) | Details → |
| ECFF | 16 | Tractor Implement Management (TIM) Client | (Byte 2) | Number of supported TIM functions &'TIM Option Byte Structure' per function to follow (valid: 0 to 240) | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) bits 2 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0001 | Guidance curvature is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0001 | Guidance curvature is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 15) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 15) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 1000 0000 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 1000 0000 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0100 0000 | Vehicle Speed change direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0010 0000 | Vehicle Speed reverse set by server is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0001 0000 | Vehicle Speed forward set by server is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 1000 | Vehicle Speed stop motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0100 | Vehicle Speed start motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0010 | Vehicle Speed in reverse direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0001 | Vehicle Speed in forward direction is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 14) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 14) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0010 | Rear hitch position is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0010 | Rear hitch position is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0001 | Rear hitch motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0001 | Rear hitch motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 13) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 13) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) bits 3 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0010 | Front hitch position is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0010 | Front hitch position is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0001 | Front hitch motion is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0001 | Front hitch motion is supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 12) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 12) 0000 0000 | No options for this option byte supported | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) bits 6 to 8 | Reserved for ISO assignment | Details → |
| CFF | 16 | Tractor Implement Management (TIM) Client | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | Details → |
| CFF | 15 | Tractor Implement Management (TIM) Server | (Byte 11) 0001 0000 | Rear PTO speed CW is supported | Details → |