Functionality and Option
To search a certain item enter you search-text into the input field and press return.
You may optionally enter a comparison operator (<, <=, >, >=, <>
or =) at the beginning of each of your search values to specify how the comparison should be done.
Displaying 1-100 of 323 results.
| Function No | Meaning | Value | Meaning | |
|---|---|---|---|---|
| 5 | Aux-N inputs | 10000000 00000000 | (1) Reserved for ISO assignment | ![]() |
| 6 | Aux-N functions | 10000000 00000000 | (1) Reserved for ISO assignment | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 10000000 | (1) Reserved for ISO assignment | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 10000000 | (1) Reserved for ISO assignment | ![]() |
| 11 | Task Controller Section Control (TC-SC) Server | 1 to 255 | (1) Number of supported booms | ![]() |
| 11 | Task Controller Section Control (TC-SC) Server | 1 to 255 | (2) Number of supported sections | ![]() |
| 12 | Task Controller Section Control (TC-SC) Client | 1 to 255 | (1) Number of supported booms | ![]() |
| 12 | Task Controller Section Control (TC-SC) Client | 1 to 255 | (2) Number of supported sections | ![]() |
| 5 | Aux-N inputs | 01000000 00000000 | (1) Supports type 14 function | ![]() |
| 6 | Aux-N functions | 01000000 00000000 | (1) Supports type 14 function | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 01000000 | (1) Reserved for ISO assignment | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 01000000 | (1) Reserved for ISO assignment | ![]() |
| 5 | Aux-N inputs | 00100000 00000000 | (1) Supports type 13 function | ![]() |
| 6 | Aux-N functions | 00100000 00000000 | (1) Supports type 13 function | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 00100000 | (1) Guidance option (G) | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 00100000 | (1) Guidance option (G) | ![]() |
| 0 | Minimum Control Function | 00010000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 5 | Aux-N inputs | 00010000 00000000 | (1) Supports type 12 function | ![]() |
| 6 | Aux-N functions | 00010000 00000000 | (1) Supports type 12 function | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 00010000 | (1) Front hitch option (F) | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 00010000 | (1) Front hitch option (F) | ![]() |
| 3 | Aux-O inputs | 00001000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 4 | Aux-O functions | 00001000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 26 | ISOBUS System Information (INFO) Server | 00001000 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 5 | Aux-N inputs | 00001000 00000000 | (1) Supports type 11 function | ![]() |
| 6 | Aux-N functions | 00001000 00000000 | (1) Supports type 11 function | ![]() |
| 0 | Minimum Control Function | 00001000 | (1) Support of Heartbeat consumer | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 00001000 | (1) Navigation option (N) | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 00001000 | (1) Navigation option (N) | ![]() |
| 5 | Aux-N inputs | 00000100 00000000 | (1) Supports type 10 function | ![]() |
| 6 | Aux-N functions | 00000100 00000000 | (1) Supports type 10 function | ![]() |
| 0 | Minimum Control Function | 00000100 | (1) Support of Heartbeat producer | ![]() |
| 3 | Aux-O inputs | 00000100 | (1) Supports type 2 function | ![]() |
| 4 | Aux-O functions | 00000100 | (1) Supports type 2 function | ![]() |
| 26 | ISOBUS System Information (INFO) Server | 00000100 | (1) Support of CAN trace possibility | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 00000100 | (1) Lighting option (L) | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 00000100 | (1) Class required lighting (L) | ![]() |
| 24 | Datalogger (LOG) Server | 00000010 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 9 | Task Controller Geo (TC-GEO) Server | 00000010 to 10000000 | (2) Reserved for ISO assignment | ![]() |
| 5 | Aux-N inputs | 00000010 00000000 | (1) Supports type 9 function | ![]() |
| 6 | Aux-N functions | 00000010 00000000 | (1) Supports type 9 function | ![]() |
| 0 | Minimum Control Function | 00000010 | (1) Type II ECU – Internal end-point termination | ![]() |
| 3 | Aux-O inputs | 00000010 | (1) Supports type 1 function | ![]() |
| 4 | Aux-O functions | 00000010 | (1) Supports type 1 function | ![]() |
| 26 | ISOBUS System Information (INFO) Server | 00000010 | (1) Support of diagnostic data export | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 00000010 | (1) Class 2, no options | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 00000010 | (1) Class 2, no options | ![]() |
| 1 | Universal Terminal (UT) Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 2 | Universal Terminal (UT) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 17 | File Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 18 | File Server Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 19 | Sequence Controller (SQC) Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 20 | Sequence Controller (SQC) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 21 | ISOBUS Shortcut Button (ISB) Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 7 | Task Controller Basic (TC-BAS) Server | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 22 | ISOBUS Shortcut Button (ISB) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 8 | Task Controller Basic (TC-BAS) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 25 | Datalogger (LOG) Client | 00000001 to 10000000 | (1) Reserved for ISO assignment | ![]() |
| 5 | Aux-N inputs | 00000001 00000000 | (1) Supports type 8 function | ![]() |
| 6 | Aux-N functions | 00000001 00000000 | (1) Supports type 8 function | ![]() |
| 0 | Minimum Control Function | 00000001 | (1) Type I ECU – Internal weak termination | ![]() |
| 3 | Aux-O inputs | 00000001 | (1) Supports type 0 function | ![]() |
| 4 | Aux-O functions | 00000001 | (1) Supports type 0 function | ![]() |
| 24 | Datalogger (LOG) Server | 00000001 | (1) Data logger (LOG) service type supports FMIS interface | ![]() |
| 9 | Task Controller Geo (TC-GEO) Server | 00000001 | (2) Polygon-based prescription maps are supported | ![]() |
| 26 | ISOBUS System Information (INFO) Server | 00000001 | (1) Support of onboard visualization | ![]() |
| 13 | Basic Tractor ECU (TECU) Server | 00000001 | (1) Class 1, no options | ![]() |
| 14 | Basic Tractor ECU (TECU) Client | 00000001 | (1) Class 1, no options | ![]() |
| 5 | Aux-N inputs | 00000000 10000000 | (1) Supports type 7 function | ![]() |
| 6 | Aux-N functions | 00000000 10000000 | (1) Supports type 7 function | ![]() |
| 5 | Aux-N inputs | 00000000 01000000 | (1) Supports type 6 function | ![]() |
| 6 | Aux-N functions | 00000000 01000000 | (1) Supports type 6 function | ![]() |
| 5 | Aux-N inputs | 00000000 00100000 | (1) Supports type 5 function | ![]() |
| 6 | Aux-N functions | 00000000 00100000 | (1) Supports type 5 function | ![]() |
| 5 | Aux-N inputs | 00000000 00010000 | (1) Supports type 4 function | ![]() |
| 6 | Aux-N functions | 00000000 00010000 | (1) Supports type 4 function | ![]() |
| 5 | Aux-N inputs | 00000000 00001000 | (1) Supports type 3 function | ![]() |
| 6 | Aux-N functions | 00000000 00001000 | (1) Supports type 3 function | ![]() |
| 5 | Aux-N inputs | 00000000 00000100 | (1) Supports type 2 function | ![]() |
| 6 | Aux-N functions | 00000000 00000100 | (1) Supports type 2 function | ![]() |
| 5 | Aux-N inputs | 00000000 00000010 | (1) Supports type 1 function | ![]() |
| 6 | Aux-N functions | 00000000 00000010 | (1) Supports type 1 function | ![]() |
| 5 | Aux-N inputs | 00000000 00000001 | (1) Supports type 0 function | ![]() |
| 6 | Aux-N functions | 00000000 00000001 | (1) Supports type 0 function | ![]() |
| 5 | Aux-N inputs | 00000000 00000000 | (1) No options | ![]() |
| 6 | Aux-N functions | 00000000 00000000 | (1) No options | ![]() |
| 0 | Minimum Control Function | 00000000 | (1) No options (Option Number in brackets) | ![]() |
| 1 | Universal Terminal (UT) Server | 00000000 | (1) No options | ![]() |
| 2 | Universal Terminal (UT) Client | 00000000 | (1) No options | ![]() |
| 3 | Aux-O inputs | 00000000 | (1) No options | ![]() |
| 4 | Aux-O functions | 00000000 | (1) No options | ![]() |
| 17 | File Server | 00000000 | (1) No options | ![]() |
| 18 | File Server Client | 00000000 | (1) No options | ![]() |
| 19 | Sequence Controller (SQC) Server | 00000000 | (1) No options | ![]() |
| 20 | Sequence Controller (SQC) Client | 00000000 | (1) No options | ![]() |
| 21 | ISOBUS Shortcut Button (ISB) Server | 00000000 | (1) No options | ![]() |
| 7 | Task Controller Basic (TC-BAS) Server | 00000000 | (1) No options | ![]() |
| 22 | ISOBUS Shortcut Button (ISB) Client | 00000000 | (1) No options | ![]() |
| 8 | Task Controller Basic (TC-BAS) Client | 00000000 | (1) No options | ![]() |
| 24 | Datalogger (LOG) Server | 00000000 | (1) No options for this option byte supported | ![]() |