CFF / ECFFFunction NoMeaningValueMeaning 
  
CFF15Tractor Implement Management (TIM) Server(Byte 15) 0000 0001Guidance curvature is supportedDetails →
CFF15Tractor Implement Management (TIM) Server(Byte 15) bits 2 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0001Aux valve 1 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0010Aux valve 1 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 0100Aux valve 2 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0000 1000Aux valve 2 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0001 0000Aux valve 3 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0010 0000Aux valve 3 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 0100 0000Aux valve 4 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 1) 1000 0000Aux valve 4 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0001Aux valve 5 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0010Aux valve 5 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 0100Aux valve 6 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0000 1000Aux valve 6 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0001 0000Aux valve 7 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0010 0000Aux valve 7 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 0100 0000Aux valve 8 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 2) 1000 0000Aux valve 8 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0001Aux valve 9 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0010Aux valve 9 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 0100Aux valve 10 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0000 1000Aux valve 10 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0001 0000Aux valve 11 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0010 0000Aux valve 11 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 0100 0000Aux valve 12 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 3) 1000 0000Aux valve 12 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0001Aux valve 13 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0010Aux valve 13 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 0100Aux valve 14 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0000 1000Aux valve 14 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0001 0000Aux valve 15 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0010 0000Aux valve 15 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 0100 0000Aux valve 16 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 4) 1000 0000Aux valve 16 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0001Aux valve 17 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0010Aux valve 17 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 0100Aux valve 18 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0000 1000Aux valve 18 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0001 0000Aux valve 19 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0010 0000Aux valve 19 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 0100 0000Aux valve 20 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 5) 1000 0000Aux valve 20 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0001Aux valve 21 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0010Aux valve 21 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 0100Aux valve 22 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0000 1000Aux valve 22 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0001 0000Aux valve 23 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0010 0000Aux valve 23 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 0100 0000Aux valve 24 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 6) 1000 0000Aux valve 24 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0000No options for this option byte supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0001Aux valve 25 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0010Aux valve 25 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 0100Aux valve 26 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0000 1000Aux valve 26 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0001 0000Aux valve 27 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0010 0000Aux valve 27 flow is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 0100 0000Aux valve 28 state is supportedDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 7) 1000 0000Aux valve 28 flow is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0000No optionsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0000No options for this option byte supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0001Type I ECU – Internal weak termination Details →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0001Aux valve 29 state is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0010Type II ECU – Internal end-point terminationDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0010Aux valve 29 flow is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 0100Support of Heartbeat producerDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 0100Aux valve 30 state is supportedDetails →
CFF0Minimum Control Function(Byte 1) 0000 1000Support of Heartbeat consumerDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0000 1000Aux valve 30 flow is supportedDetails →
CFF0Minimum Control Function(Byte 1) bits 5 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0001 0000Aux valve 31 state is supportedDetails →
CFF1Universal Terminal (UT) Server(Byte 1) 0000 0000No optionsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0010 0000Aux valve 31 flow is supportedDetails →
CFF1Universal Terminal (UT) Server(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 0100 0000Aux valve 32 state is supportedDetails →
CFF2Universal Terminal (UT) Client(Byte 1) 0000 0000No optionsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 8) 1000 0000Aux valve 32 flow is supportedDetails →
CFF2Universal Terminal (UT) Client(Byte 1) bits 1 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 9) bits 1 to 6, values 0 to 32Amount of supported auxiliary valvesDetails →
CFF3Aux-O inputs(Byte 1) 0000 0000No optionsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 9) bits 7 to 8Reserved for ISO assignmentDetails →
CFF3Aux-O inputs(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0000No options for this option byte supportedDetails →
CFF3Aux-O inputs(Byte 1) 0000 0010Supports type 1 functionDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0001Front PTO disengagement is supportedDetails →
CFF3Aux-O inputs(Byte 1) 0000 0100Supports type 2 functionDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0010Front PTO engagement CCW is supportedDetails →
CFF3Aux-O inputs(Byte 1) bits 4 to 8Reserved for ISO assignmentDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 0100Front PTO engagement CW is supportedDetails →
CFF4Aux-O functions(Byte 1) 0000 0000No optionsDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0000 1000Front PTO speed CCW is supportedDetails →
CFF4Aux-O functions(Byte 1) 0000 0001Supports type 0 functionDetails →
CFF16Tractor Implement Management (TIM) Client(Byte 10) 0001 0000Front PTO speed CW is supportedDetails →
CFF4Aux-O functions(Byte 1) 0000 0010Supports type 1 functionDetails →